{"id":78,"date":"2023-05-22T14:20:11","date_gmt":"2023-05-22T14:20:11","guid":{"rendered":"https:\/\/ekitap.ankara.edu.tr\/dentures\/chapter\/c-dislere-ve-dissiz-alanlara-iletilen-stresin-dengelenmesi\/"},"modified":"2025-09-10T12:05:06","modified_gmt":"2025-09-10T12:05:06","slug":"c-dislere-ve-dissiz-alanlara-iletilen-stresin-dengelenmesi","status":"publish","type":"chapter","link":"https:\/\/ekitap.ankara.edu.tr\/dentures\/chapter\/c-dislere-ve-dissiz-alanlara-iletilen-stresin-dengelenmesi\/","title":{"raw":"Balancing the stress transmitted to teeth and edentulous areas","rendered":"Balancing the stress transmitted to teeth and edentulous areas"},"content":{"raw":"<h2><strong>Reducing the number of artificial teeth in the posterior region<\/strong><\/h2>\r\nBy reducing the number of artificial teeth in the denture base of the posterior region, the aim is to limit the area of the denture exposed to masticatory forces.\r\n<h2><strong>Reducing the buccolingual width of artificial teeth<\/strong><\/h2>\r\nAnother method of narrowing the area of the denture exposed to masticatory forces is the selection of artificial teeth with reduced buccolingual width. This not only decreases the amount of force transmitted to the tissues beneath the denture base, but also limits the amount of movement in the denture base under force, thereby minimizing the torque transmitted to the abutment teeth.\r\n<h2><strong>Preservation of the sharpness of the cusps<\/strong><\/h2>\r\nDuring occlusal adjustments, the sharpness of the cusps of the artificial teeth is preserved to enhance masticatory efficiency while minimizing the required masticatory forces for function. In this way, the amount of stress transmitted to the supporting tissues is controlled.\r\n<h2><strong>Neuromuscular control<\/strong><\/h2>\r\nThe patient's ability to control the movements of the lips, cheeks, and tongue plays a key role in the retention of the prosthesis and, consequently, in reducing the stress transmitted to the supporting tissues. However, the design of the denture base and its polished surfaces significantly affect the patient's ability to maintain the prosthesis in place.\r\n<h2><strong>Rigid major connector<\/strong><\/h2>\r\nTo reduce movements around different fulcrum axes in the distal extension denture base and ensure that the load is distributed evenly across both sides of the arch, including the abutment teeth and edentulous areas, the major connectors must be rigid. By extending the denture base with a rigid major connector to the teeth on the opposite side of the arch and supporting the prosthesis with various direct retainers, denture base movements and stresses can be minimized.\r\n<h2><strong>Direct retention<\/strong><\/h2>\r\nIn the retention of the prosthesis and the control of stresses, the relationship between the abutment tooth's height of contour and the position of the retentive clasp arm is more important than the number of clasps, as the retentive clasp arm is the component of the partial denture that transmits potentially damaging forces to the abutment teeth. In the planning of RPDs, the use of an excessive number of clasps has become a common practice. The number of clasps to be used in the treatment planning of RPD is based on the modification spaces in the Kennedy classification; however, one of the most common mistakes is placing a clasp on every abutment tooth, which is an incorrect approach.\r\n\r\nThe ideal clasp configuration is the quadrilateral design. In a prosthesis securely supported by four clasps, both retention and leverage effects are balanced (Figure 1-37).\r\n\r\n&nbsp;\r\n\r\n[caption id=\"attachment_75\" align=\"alignnone\" width=\"381\"]<img class=\"wp-image-75\" src=\"https:\/\/ekitap.ankara.edu.tr\/wp-content\/uploads\/sites\/29\/2023\/05\/Sekil1.37-300x215.jpg\" alt=\"Figure 1-37. In the quadrilateral clasp design, a clasp is placed at both ends of the edentulous space. This arrangement provides maximum retention and stability.\" width=\"381\" height=\"273\" \/> <strong>Figure 1-37.<\/strong> In the quadrilateral clasp design, a clasp is placed at both ends of the edentulous space. This arrangement provides maximum retention and stability.[\/caption]\r\n\r\nWhen determining the positions of the clasps, those on both sides are placed on the most posterior teeth possible, while the others are positioned in the anterior region to the extent allowed by aesthetics.\r\n\r\nThe triangular (or tripod) design, which involves three abutment teeth, is also advantageous. By keeping the abutments as far apart as possible, the retentive clasps and the prosthesis will be positioned over the widest possible area (Figure 1-38).\r\n\r\n[caption id=\"attachment_76\" align=\"alignnone\" width=\"388\"]<img class=\"wp-image-76\" style=\"color: #373d3f;font-weight: bold;font-size: 1em\" src=\"http:\/\/ekitap.ankara.edu.tr\/dentures\/wp-content\/uploads\/sites\/29\/2025\/04\/Sekil1.38-300x216.jpg\" alt=\"Figure 1-38. The triangular clasp design is the most ideal clasp configuration in Class II cases with modification spaces.\" width=\"388\" height=\"279\" \/> <strong>Figure 1-38.<\/strong> The triangular clasp design for Class II cases with modification spaces.[\/caption]\r\n\r\nThe triangular clasp design is the most ideal clasp configuration in Class II cases with modification spaces.The bilateral clasp design, typically achieved by using one clasp on each side of the dental arch, is not as advantageous as other designs. However, when the number of abutment teeth is limited, it is unfortunately the only option. Clasps are used on both sides of the arch without considering the position of the terminal abutment teeth. The resistance of the clasps in the bilateral design to the leverage-induced stresses created by the denture base is minimal (Figure 1-39).\r\n\r\n&nbsp;\r\n\r\n[caption id=\"attachment_77\" align=\"alignnone\" width=\"395\"]<img class=\"wp-image-77\" src=\"https:\/\/ekitap.ankara.edu.tr\/wp-content\/uploads\/sites\/29\/2025\/04\/Sekil1.39-300x214.jpg\" alt=\"Figure 1-39. The bilateral clasp design is used in Class I cases.\" width=\"395\" height=\"282\" \/> <strong>Figure 1-39.<\/strong> The bilateral clasp design is used in Class I cases.[\/caption]\r\n<h2><strong>Indirect retention<\/strong><\/h2>\r\nBy preventing the distal extension denture base from rotating away from the mucosa around the fulcrum axis, the indirect retainer helps to promote stability by preventing denture base movement. The indirect retainer, which is situated on the other side of the fulcrum axis in relation to the denture base, makes use of the lever's mechanical advantage and only functions when the denture base rotates away from the mucosa around the fulcrum axis (<a href=\"https:\/\/ekitap.ankara.edu.tr\/dentures\/part\/4-bolumprotez-bilesenleri-indirekt-tutucular\/\">See: Indirect Retainers; Ch 4<\/a>).\r\n\r\n&nbsp;","rendered":"<h2><strong>Reducing the number of artificial teeth in the posterior region<\/strong><\/h2>\n<p>By reducing the number of artificial teeth in the denture base of the posterior region, the aim is to limit the area of the denture exposed to masticatory forces.<\/p>\n<h2><strong>Reducing the buccolingual width of artificial teeth<\/strong><\/h2>\n<p>Another method of narrowing the area of the denture exposed to masticatory forces is the selection of artificial teeth with reduced buccolingual width. This not only decreases the amount of force transmitted to the tissues beneath the denture base, but also limits the amount of movement in the denture base under force, thereby minimizing the torque transmitted to the abutment teeth.<\/p>\n<h2><strong>Preservation of the sharpness of the cusps<\/strong><\/h2>\n<p>During occlusal adjustments, the sharpness of the cusps of the artificial teeth is preserved to enhance masticatory efficiency while minimizing the required masticatory forces for function. In this way, the amount of stress transmitted to the supporting tissues is controlled.<\/p>\n<h2><strong>Neuromuscular control<\/strong><\/h2>\n<p>The patient&#8217;s ability to control the movements of the lips, cheeks, and tongue plays a key role in the retention of the prosthesis and, consequently, in reducing the stress transmitted to the supporting tissues. However, the design of the denture base and its polished surfaces significantly affect the patient&#8217;s ability to maintain the prosthesis in place.<\/p>\n<h2><strong>Rigid major connector<\/strong><\/h2>\n<p>To reduce movements around different fulcrum axes in the distal extension denture base and ensure that the load is distributed evenly across both sides of the arch, including the abutment teeth and edentulous areas, the major connectors must be rigid. By extending the denture base with a rigid major connector to the teeth on the opposite side of the arch and supporting the prosthesis with various direct retainers, denture base movements and stresses can be minimized.<\/p>\n<h2><strong>Direct retention<\/strong><\/h2>\n<p>In the retention of the prosthesis and the control of stresses, the relationship between the abutment tooth&#8217;s height of contour and the position of the retentive clasp arm is more important than the number of clasps, as the retentive clasp arm is the component of the partial denture that transmits potentially damaging forces to the abutment teeth. In the planning of RPDs, the use of an excessive number of clasps has become a common practice. The number of clasps to be used in the treatment planning of RPD is based on the modification spaces in the Kennedy classification; however, one of the most common mistakes is placing a clasp on every abutment tooth, which is an incorrect approach.<\/p>\n<p>The ideal clasp configuration is the quadrilateral design. In a prosthesis securely supported by four clasps, both retention and leverage effects are balanced (Figure 1-37).<\/p>\n<p>&nbsp;<\/p>\n<figure id=\"attachment_75\" aria-describedby=\"caption-attachment-75\" style=\"width: 381px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-75\" src=\"https:\/\/ekitap.ankara.edu.tr\/wp-content\/uploads\/sites\/29\/2023\/05\/Sekil1.37-300x215.jpg\" alt=\"Figure 1-37. In the quadrilateral clasp design, a clasp is placed at both ends of the edentulous space. This arrangement provides maximum retention and stability.\" width=\"381\" height=\"273\" srcset=\"https:\/\/ekitap.ankara.edu.tr\/dentures\/wp-content\/uploads\/sites\/29\/2023\/05\/Sekil1.37-300x215.jpg 300w, https:\/\/ekitap.ankara.edu.tr\/dentures\/wp-content\/uploads\/sites\/29\/2023\/05\/Sekil1.37-65x47.jpg 65w, https:\/\/ekitap.ankara.edu.tr\/dentures\/wp-content\/uploads\/sites\/29\/2023\/05\/Sekil1.37-225x161.jpg 225w, https:\/\/ekitap.ankara.edu.tr\/dentures\/wp-content\/uploads\/sites\/29\/2023\/05\/Sekil1.37-350x251.jpg 350w, https:\/\/ekitap.ankara.edu.tr\/dentures\/wp-content\/uploads\/sites\/29\/2023\/05\/Sekil1.37.jpg 441w\" sizes=\"auto, (max-width: 381px) 100vw, 381px\" \/><figcaption id=\"caption-attachment-75\" class=\"wp-caption-text\"><strong>Figure 1-37.<\/strong> In the quadrilateral clasp design, a clasp is placed at both ends of the edentulous space. This arrangement provides maximum retention and stability.<\/figcaption><\/figure>\n<p>When determining the positions of the clasps, those on both sides are placed on the most posterior teeth possible, while the others are positioned in the anterior region to the extent allowed by aesthetics.<\/p>\n<p>The triangular (or tripod) design, which involves three abutment teeth, is also advantageous. By keeping the abutments as far apart as possible, the retentive clasps and the prosthesis will be positioned over the widest possible area (Figure 1-38).<\/p>\n<figure id=\"attachment_76\" aria-describedby=\"caption-attachment-76\" style=\"width: 388px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-76\" style=\"color: #373d3f;font-weight: bold;font-size: 1em\" src=\"http:\/\/ekitap.ankara.edu.tr\/dentures\/wp-content\/uploads\/sites\/29\/2025\/04\/Sekil1.38-300x216.jpg\" alt=\"Figure 1-38. The triangular clasp design is the most ideal clasp configuration in Class II cases with modification spaces.\" width=\"388\" height=\"279\" srcset=\"https:\/\/ekitap.ankara.edu.tr\/dentures\/wp-content\/uploads\/sites\/29\/2025\/04\/Sekil1.38-300x216.jpg 300w, https:\/\/ekitap.ankara.edu.tr\/dentures\/wp-content\/uploads\/sites\/29\/2025\/04\/Sekil1.38-65x47.jpg 65w, https:\/\/ekitap.ankara.edu.tr\/dentures\/wp-content\/uploads\/sites\/29\/2025\/04\/Sekil1.38-225x162.jpg 225w, https:\/\/ekitap.ankara.edu.tr\/dentures\/wp-content\/uploads\/sites\/29\/2025\/04\/Sekil1.38-350x251.jpg 350w, https:\/\/ekitap.ankara.edu.tr\/dentures\/wp-content\/uploads\/sites\/29\/2025\/04\/Sekil1.38.jpg 412w\" sizes=\"auto, (max-width: 388px) 100vw, 388px\" \/><figcaption id=\"caption-attachment-76\" class=\"wp-caption-text\"><strong>Figure 1-38.<\/strong> The triangular clasp design for Class II cases with modification spaces.<\/figcaption><\/figure>\n<p>The triangular clasp design is the most ideal clasp configuration in Class II cases with modification spaces.The bilateral clasp design, typically achieved by using one clasp on each side of the dental arch, is not as advantageous as other designs. However, when the number of abutment teeth is limited, it is unfortunately the only option. Clasps are used on both sides of the arch without considering the position of the terminal abutment teeth. The resistance of the clasps in the bilateral design to the leverage-induced stresses created by the denture base is minimal (Figure 1-39).<\/p>\n<p>&nbsp;<\/p>\n<figure id=\"attachment_77\" aria-describedby=\"caption-attachment-77\" style=\"width: 395px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-77\" src=\"https:\/\/ekitap.ankara.edu.tr\/wp-content\/uploads\/sites\/29\/2025\/04\/Sekil1.39-300x214.jpg\" alt=\"Figure 1-39. The bilateral clasp design is used in Class I cases.\" width=\"395\" height=\"282\" srcset=\"https:\/\/ekitap.ankara.edu.tr\/dentures\/wp-content\/uploads\/sites\/29\/2025\/04\/Sekil1.39-300x214.jpg 300w, https:\/\/ekitap.ankara.edu.tr\/dentures\/wp-content\/uploads\/sites\/29\/2025\/04\/Sekil1.39-65x46.jpg 65w, https:\/\/ekitap.ankara.edu.tr\/dentures\/wp-content\/uploads\/sites\/29\/2025\/04\/Sekil1.39-225x161.jpg 225w, https:\/\/ekitap.ankara.edu.tr\/dentures\/wp-content\/uploads\/sites\/29\/2025\/04\/Sekil1.39-350x250.jpg 350w, https:\/\/ekitap.ankara.edu.tr\/dentures\/wp-content\/uploads\/sites\/29\/2025\/04\/Sekil1.39.jpg 412w\" sizes=\"auto, (max-width: 395px) 100vw, 395px\" \/><figcaption id=\"caption-attachment-77\" class=\"wp-caption-text\"><strong>Figure 1-39.<\/strong> The bilateral clasp design is used in Class I cases.<\/figcaption><\/figure>\n<h2><strong>Indirect retention<\/strong><\/h2>\n<p>By preventing the distal extension denture base from rotating away from the mucosa around the fulcrum axis, the indirect retainer helps to promote stability by preventing denture base movement. The indirect retainer, which is situated on the other side of the fulcrum axis in relation to the denture base, makes use of the lever&#8217;s mechanical advantage and only functions when the denture base rotates away from the mucosa around the fulcrum axis (<a href=\"https:\/\/ekitap.ankara.edu.tr\/dentures\/part\/4-bolumprotez-bilesenleri-indirekt-tutucular\/\">See: Indirect Retainers; Ch 4<\/a>).<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"author":3,"menu_order":13,"template":"","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"_uf_show_specific_survey":0,"_uf_disable_surveys":false,"pb_show_title":"on","pb_short_title":"","pb_subtitle":"","pb_authors":[],"pb_section_license":""},"chapter-type":[],"contributor":[],"license":[],"class_list":["post-78","chapter","type-chapter","status-publish","hentry"],"part":21,"_links":{"self":[{"href":"https:\/\/ekitap.ankara.edu.tr\/dentures\/wp-json\/pressbooks\/v2\/chapters\/78","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ekitap.ankara.edu.tr\/dentures\/wp-json\/pressbooks\/v2\/chapters"}],"about":[{"href":"https:\/\/ekitap.ankara.edu.tr\/dentures\/wp-json\/wp\/v2\/types\/chapter"}],"author":[{"embeddable":true,"href":"https:\/\/ekitap.ankara.edu.tr\/dentures\/wp-json\/wp\/v2\/users\/3"}],"version-history":[{"count":14,"href":"https:\/\/ekitap.ankara.edu.tr\/dentures\/wp-json\/pressbooks\/v2\/chapters\/78\/revisions"}],"predecessor-version":[{"id":1533,"href":"https:\/\/ekitap.ankara.edu.tr\/dentures\/wp-json\/pressbooks\/v2\/chapters\/78\/revisions\/1533"}],"part":[{"href":"https:\/\/ekitap.ankara.edu.tr\/dentures\/wp-json\/pressbooks\/v2\/parts\/21"}],"metadata":[{"href":"https:\/\/ekitap.ankara.edu.tr\/dentures\/wp-json\/pressbooks\/v2\/chapters\/78\/metadata\/"}],"wp:attachment":[{"href":"https:\/\/ekitap.ankara.edu.tr\/dentures\/wp-json\/wp\/v2\/media?parent=78"}],"wp:term":[{"taxonomy":"chapter-type","embeddable":true,"href":"https:\/\/ekitap.ankara.edu.tr\/dentures\/wp-json\/pressbooks\/v2\/chapter-type?post=78"},{"taxonomy":"contributor","embeddable":true,"href":"https:\/\/ekitap.ankara.edu.tr\/dentures\/wp-json\/wp\/v2\/contributor?post=78"},{"taxonomy":"license","embeddable":true,"href":"https:\/\/ekitap.ankara.edu.tr\/dentures\/wp-json\/wp\/v2\/license?post=78"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}